Iodine value explained — HuaQuan Carbon technical article

Home / Articles / Iodine value explained

2026-10-28Test methods6 min read

What an iodine value of 900 mg/g actually tells you

Iodine number measures micropores below 2 nanometres. It says almost nothing about decolourisation. Here is the number you should ask for instead.

Iodine value is the first number on every specification sheet and the most misused number in the industry. A buyer who understands what it measures — and what it does not — will make better purchasing decisions than one who simply pays for the higher figure.

What the test actually measures

The iodine number is a single-point adsorption test: a weighed carbon sample is dosed into a standard iodine solution, equilibrated, and the remaining iodine is titrated. Iodine is a small molecule, roughly 0.5 nanometres across, so it fills pores below about 2 nm — the micropore fraction. The result, expressed in mg of iodine adsorbed per gram of carbon, is a reasonable proxy for micropore surface area. Methods are standardised (ASTM D4607, GB/T 7702), so a 900 mg/g from one laboratory should mean the same thing as a 900 mg/g from another.

That is the useful half of the story. The useless half: iodine tells you nothing about the mesopores — the 2–50 nm pores that colour bodies, humic substances, oil droplets and many industrial organics require. A carbon can carry an impressive iodine value and still be nearly useless for decolourisation.

DutyPore regime usedDoes iodine value predict it?
DechlorinationmicroporeYes — primary number
Taste & odour (geosmin, MIB)microporeYes — primary number
Gold cyanide adsorptionmicroporeYes — primary number
Gas-phase VOC (small solvents)microporePartly — CTC is the duty number
Decolourisation (sugar, oil)mesoporeNo — use methylene blue / molasses
Humic / NOM removalmesoporeNo — use tannin value

What the number does predict

Within its domain, iodine value is honest. For small-molecule duties — dechlorination, taste and odour, gold cyanide adsorption, gas-phase micropore capacity — it tracks capacity well enough to compare grades and batches. Between a 900 and a 1,100 coconut carbon on a gold circuit, the difference is real money and real kinetics.

The failure mode is extrapolation: using a micropore number to judge a mesopore duty. Decolourisation asked for in iodine value gets answered with a bigger micropore fraction — capacity the colour molecule cannot reach — and the buyer pays for pores that stay empty.

The numbers to ask for instead

None of this makes iodine value worthless. It makes it scoped: the right first filter for small-molecule duty, the wrong only number for everything else. When a quotation leads with iodine value alone, ask for the second number — how a supplier answers that question tells you what kind of supplier you are talking to.

Rule of thumb. Micropore duty, compare iodine values. Mesopore duty, compare methylene blue and molasses numbers. Unknown duty — ask for both, then test the stream.

More from the article index

Ten technical notes · no email gate

2026 · 10 · 09

PFAS removal with GAC: contact time, bed life and the cost of undersizing

Empty bed contact time drives everything. Sizing a train for long-chain PFAS without over-building the contactor — and knowing where GAC stops.

Application · 11 min
2026 · 08 · 30

Hardness, abrasion number and why your gold carbon disappears

Attrition loss never shows on the invoice and always shows in the elution balance. Reading hardness data as a wear-rate prediction.

Test methods · 5 min
2026 · 07 · 24

Seasonal taste and odour events: sizing PAC dose from a jar test

Algal blooms arrive faster than bed changes. Building a dose-response curve you can trust when the phone rings.

Application · 6 min
2026 · 06 · 15

What to put in an RFQ for activated carbon

Twelve lines that separate a comparable quotation from a price on a bag, with a sample specification you can copy.

Procurement · 10 min

← All articles

Send the analysis. Receive a grade, not a brochure.

Contaminant, inlet level, flow rate, target limit — four numbers are enough for a first recommendation and a media volume estimate.