An algal bloom does not schedule itself around your capital plan. Taste and odour events arrive in days; a GAC bed change takes weeks. This is why every utility keeps powdered activated carbon in the store even when a permanent bed exists — PAC is the fast answer, dosed into the existing train, no capital and no change-out. The whole game is knowing the dose before the phone rings.
A dose-response curve built from a jar test is the difference between dosing and guessing. The protocol that produces a usable curve:
| Dose (mg/L) | Geosmin removal @ 30 min | MIB removal @ 30 min | Comment |
|---|---|---|---|
| 5 | ~40% | ~35% | Marginal — event starting |
| 10 | ~65% | ~60% | Usual first operating dose |
| 20 | ~85% | ~80% | Typical bloom response |
| 50 | ~97% | ~95% | Severe event / short contact |
Illustrative curve for a high-iodine wood PAC on reservoir water — real numbers come from a jar test on your water, which is the point of this article.
The jar curve gives equilibrium capacity; the plant runs on kinetics. Convert with three adjustments:
Size the standing inventory from the worst historical event, not the average one: event duration × peak dose × design flow, plus a margin. PAC holds for years when stored dry — the carrying cost of a serious stockpile is trivial next to the cost of a public taste complaint. Send us a jar sample from the event and we return the dose-response curve for the exact grade, which turns next year's bloom from an emergency into a procurement line item.
Ten technical notes · no email gate
Why acid-washed grades exist, what they remove, and when the extra cost is justified by the regulatory limit you must meet.
A jar test says whether carbon adsorbs. A column test says when the bed breaks through. How to run one that survives contact with the plant.
Iodine number measures micropores below 2 nanometres. It says almost nothing about decolourisation. Here is the number you should ask for instead.
Finer mesh buys kinetics and costs pressure drop. Picking a split from vessel size, backwash rate and allowable head loss — not from habit.
Contaminant, inlet level, flow rate, target limit — four numbers are enough for a first recommendation and a media volume estimate.