Manufacturer & exporter · Zhengzhou, Henan, China
ISO 9001 · ISO 14001 · SGS / CCIC inspected shawn@huaquan.com · +86 158 3821 7999 · WhatsApp
Request a Quote
PAC dose and jar testing — HuaQuan Carbon technical article

Home / Articles / PAC dose and jar testing

2026-07-24Application6 min read

Seasonal taste and odour events: sizing PAC dose from a jar test

Algal blooms arrive faster than bed changes. Building a dose-response curve you can trust when the phone rings.

An algal bloom does not schedule itself around your capital plan. Taste and odour events arrive in days; a GAC bed change takes weeks. This is why every utility keeps powdered activated carbon in the store even when a permanent bed exists — PAC is the fast answer, dosed into the existing train, no capital and no change-out. The whole game is knowing the dose before the phone rings.

The jar test, done properly

A dose-response curve built from a jar test is the difference between dosing and guessing. The protocol that produces a usable curve:

Dose (mg/L)Geosmin removal @ 30 minMIB removal @ 30 minComment
5~40%~35%Marginal — event starting
10~65%~60%Usual first operating dose
20~85%~80%Typical bloom response
50~97%~95%Severe event / short contact

Illustrative curve for a high-iodine wood PAC on reservoir water — real numbers come from a jar test on your water, which is the point of this article.

From curve to operating dose

The jar curve gives equilibrium capacity; the plant runs on kinetics. Convert with three adjustments:

Stock policy

Size the standing inventory from the worst historical event, not the average one: event duration × peak dose × design flow, plus a margin. PAC holds for years when stored dry — the carrying cost of a serious stockpile is trivial next to the cost of a public taste complaint. Send us a jar sample from the event and we return the dose-response curve for the exact grade, which turns next year's bloom from an emergency into a procurement line item.

More from the article index

Ten technical notes · no email gate

2026 · 07 · 02

Ash, leachables and the potable-water question

Why acid-washed grades exist, what they remove, and when the extra cost is justified by the regulatory limit you must meet.

Test methods · 7 min
2026 · 11 · 23

Running a column test that actually predicts bed life

A jar test says whether carbon adsorbs. A column test says when the bed breaks through. How to run one that survives contact with the plant.

Application · 8 min
2026 · 10 · 28

What an iodine value of 900 mg/g actually tells you

Iodine number measures micropores below 2 nanometres. It says almost nothing about decolourisation. Here is the number you should ask for instead.

Test methods · 6 min
2026 · 09 · 22

Mesh size is a hydraulic decision, not a quality decision

Finer mesh buys kinetics and costs pressure drop. Picking a split from vessel size, backwash rate and allowable head loss — not from habit.

Selection · 7 min

← All articles

Send the analysis. Receive a grade, not a brochure.

Contaminant, inlet level, flow rate, target limit — four numbers are enough for a first recommendation and a media volume estimate.